LABORATORY RESULTS

June 30, 2000

Sample Date : May 22, 2000 Sample Type : Drinking Water Report Date : June 30, 2000 Report Units: mg/L unless

AZ Laboratory #: AZ0401 otherwise noted.

 

Parameter / Method

Analysis

Date

MCL 1

Detection

Limit

 

Amount Found
Microbiological:
Coliform (Colilert) 05/18/00 0 0

0
pH 150.1 05/17/00 6.5-8.5 ----

7.39
Alkalinity (Total as CaCO3) 05/17/00 ---- 2.0 312.5
Hardness(as mg eq. CaCO3) 6/14/00 ---- 20.0 322.9
Total Dissolved Solids SM 2540C 5/23/00 500.0 20.0 464.0
Turbidity 180.1 05/17/00 N/A 0.1 < 1.0
Chloride 300.0 05/17/00 250.0 0.10

1.2
Nitrite-N 300.0 05/17/00 10.0 0.10 < 0.1
Nitrate-N 300.0 05/17/00 10.0 0.10 < 0.1
Phosphate-P 300.0 05/17/00 N/A 0.10 < 0.1
Fluoride 300.0 05/17/00 2.0 0.10 0.1
Sulfate 300.0 05/17/00 250.0 0.10

6.7
Cadmium(T) 200.9 06/27/00

 

0.010

0.005

< 0.005
Arsenic(T) 200.9 06/09/00 0.05 0.003

< 0.005
Calcium(T) SM 3111B 06/13/00 N/A 0.1

65.0
Chromium(T)SM 3111B 06/16/00 0.05 0.04

< 0.04
Copper(T) SM 3111B 05/22/00 1.0 < 0.04

< 0.04
Lead(T) 200.9 06/16/00 0.05 0.005 < 0.005
Mercury (T) 245.1 05/23/00 0.002 0.0002

< 0.0002
Manganese(T)SM3111B 06/29/00 0.05 0.03

< 0.03
Nickel(T) SM 3111B 06/19/00 N/A 0.04

< 0.04
Magnesium SM 3111B 06/14/00 N/A 0.01

39.0
Potassium SM 3111B 06/28/00 N/A 1.0

1.1
Selenium(T) 200.9 06/15/00 0.01 0.005

< 0.005
Silver(T) SM 3111B 05/23/00 0.05 0.02

< 0.02
Sodium SM 3111B 06/27/00 N/A 1.0

4.4
Zinc(T) SM 3111B 05/22/00 5.0 0.02

0.145

Notes:

1 - Maximum Concentration Limit.
2 – Matrix Interference may result in a low reading.
3 – Matrix Interference may result in a high reading.

(T)- indicates Total Metals by EPA Methods.

 

Coliform performed by Bolin Laboratories, Inc. Phoenix, AZ AZ0004

** - Exceeds MCL.